Accuspin micro r manual






















Description of the accuSpin™ 7 The accuSpin™ 1 / 1R The figure below shows a accuSpin™ 1R with the lid open and a swinging bucket rotor installed. Description The accuSpin™ 1R is a general-purpose tabletop cen-trifuge for biotechnological and pharmaceutic research that moves high capacity centrifugation onto the fast track. The Fisher Scientific AccuSpin Micro R Centrifuge CAT# with Microliter PP-Rotor CAT# is a compact, economical, high-speed microcentrifuge ideal for nucleic acid research and other microliter volume separations. The accuSpin™ Micro 17 is ventilated. (For the refrigerated model, see the Micro 17R, Cat. No. ) Capacity: 48mL (24 × /2mL tubes) Maximum speed/RCF: 13,rpm/17,xG. Ventilated or refrigerated models available. Easy-to-use controls with digital display. Adjustable 99 minute timer and quick-spin feature for short runs.


Centrifuge C is a non-refrigerated bench-top centrifuge and Centrifuge R is a refrigerated bench-top centrifuge. In both devices, Eppendorf Micro Test Tubes can be centrifuged at 20, rcf (14, rpm). It is possible to attain an rcf of up to 25, using a special position rotor. The Fisher Scientific AccuSpin Micro 17R is a refrigerated microcentrifuge capable of reaching speeds of 13, RPM. This small but robust machine makes spinning tissue culture samples a breeze. This benchtop refrigerated centrifuge includes a fixed angle rotor and handles a maximum of twenty-four / mL tubes. Find Thermo Centrifuge Accuspin MICRO R Fisher Scientific Accuspin Micro 17R Accuspin 17R Fisher Micro 17R Fisher Scientific Accuspin 17R 24 x / ML rotor RPM -9C to +40C as shown in photo includes 24 position rotor with cover ships tested at the best price available at Triad Scientific.


manual_Fisher_Scientific_accuSpin_MicroR_Service_Manual Identifier-ark ark://t1rg4hm2g Ocr ABBYY FineReader (Extended OCR) Ppi Scanner. Description. Compact, economical, high-speed microcentrifuges, ideal for nucleic acid research and other small-volume separations. Available in two versions: with or without refrigeration. Both are supplied with a 24 × /mL autoclavable rotor with biocontainment lid. With this rotor, units can reach speeds up to 13,rpm (16,×G). pathogenic Micro-organisms without suitable safety systems. If Microbiological samples of risk group II (accord-ing to "Laboratory Bio-safety Manual" of WHO) are being centrifuged, aerosol-ti ght bio-seals have to be used. For materials in a higher risk group, more than one precaution is required. • Should toxins or pathogenic substances.

0コメント

  • 1000 / 1000